========================================================================== Diablo Analytical EZReporter Software Advanced Reporting and Analysis for Chromatography Data Systems (c) Copyright 2010-2016 Diablo Analytical, Inc. All Rights Reserved Diablo Analytical, Inc. 5141 Lone Tree Way Antioch, CA 94531 Phone: (925) 755-1005 Fax: (925) 755-1007 E-mail: support@diabloanalytical.com WWW: http://www.diabloanalytical.com Support: http://www.diabloanalytical.com/support.htm ========================================================================== RELEASE NOTES Version: 3.0.4.4 Release Date: 12/02/2016 Software Support: ----------------- Please visit the support page of our web site: http://www.diabloanalytical.com/support.htm Version History: ---------------- [-] = Bug fix or change in behavior [+] = Enhancement [ALL] = Applies to all modules [STD] = Standard/base module [NGA] = Natural Gas Analysis Module [RDB] = Results Database Module [ADO] = Analog and Digital Output Module Version 3.0.4.4 --------------- [+] [ALL] Fixed problem with retrieving the peak summing results in the ChemStation Connector macro (ezpt.mac). [+] [ALL] Dual signed all application EXE files with both SHA1 and SHA256 certificates [+] [ALL] Signed installer with SHA256 certificate. [+] [NGA] Added new GPA2145-16 data source and upgrade guide. Version 3.0.4.3 --------------- [-] [RDB] Fixed an issue where the component results in the sample history summary table would be displayed in inverse order when a history limit is specified in the "Find Results" window. Version 3.0.4.2 --------------- [-] [ALL] Fixed an issue with the EZ Result Monitor and EZChrom Connector where the source data file is not read correctly from localized EZChrom sample information files (.SPL). This prevents the .SPL and .ESD files from related channels from being recognized properly causing problems with processing of results and deleting the related files when processing is complete. [-] [ALL] The GC Solutions Connector can now read compound results generated by Lab Solutions. Version 3.0.4.1 --------------- [-] [NGA] Fixed problem with the handling of the C6+ raw amount in extended reports that could result in incorrect normalization during reprocessing. Version 3.0.4.0 --------------- [+] [ALL] EZ IQ ISO image updated to include Fusion Connector 1.0.1.0. [-] [ALL] Entering personal information that includes an apostrophy no longer causes an error when saving the registration information in the Licsense status window. [-] [NGA] Fixed the ChemStation Connector ezrpt.mac processing macro so that it reads the compound group results Version 3.0.3.5 --------------- [+] [ALL] EZ IQ ISO image updated to include Fusion Connector 1.0.0.5. [+] [ALL] Updated default configuration files Version 3.0.3.4 --------------- [-] [RDB] Results in the CalculatedResults and ExtendedFractions tables are now deleted When deleting results from the results database. [-] [STD] Fixed defect that would prevent the component table in the configuration editor from being displayed properly for the Standard Edition or if NGA/NGL Calculations are disabled in the Natural Gas Analysis configuration. [+] [ALL] EZ IQ ISO image updated to include Fusion Connector 1.0.0.4. Version 3.0.3.3 --------------- [+] [ALL] Added a Fusion Connector to process results from the INFICON Fusion GC. It must be installed after installing EZReporter for EZ IQ and requires the .NET 4.0 Framework. [+] [ALL] Added the ability to process "Named Peak" Group results to the EZChrom, and EZ IQ Connectors. [+] [ALL] Added support for custom sample information variables to the EZChrom, EZ IQ, and Compass Connectors. Version 3.0.3.2 --------------- [-] [RDB] Fixed missing code to set heating value in KJ/mol when reprocessing from the results database. [-] [ALL] Modified the "Run EZreporter Now" option at the end of the installation so that EZReporter runs with standard permissions under UAC rather than inheriting the elevated permissions of the installation. This prevents problems with the Connector programs not being able to connect with an elevated instance of EZReporter. [+] [ALL] Added new ISO 8973 Default configuration file to the installation. [+] [NGA] Added the following new NGA calculations and results: -ISO 8973 Vapor Pressure at 37.8, 40, 50, and 70 degrees C -ISO 8973 Density at 15 degrees C [+] [NGA] Added a new ISO 8973 physical property data source. [+] [RDB] Updated the Results Database schema from version 3.03.00 to 3.04.00 to support the new ISO 8973 results. You will be prompted to upgrade existing databases when you start the software. Version 3.0.3.1 --------------- [+] [NGA] Added new context menu to the Standard Components table that allows you to create "Combined Components" - combinations of multiple components with physical constants that are either averaged or weighted. Check the desired components to combine, right-click and select "Create Combined COmponent". Version 3.0.3.0 --------------- [+] [NGA] Added the following new NGA/NGL calculations and results: -Gross Heating Value BTU/lbm as a liquid -Gross Heating Value BTU/Gallon as a dry gas calculated from the product of the component BTU/lbm and absolute liquid density lbm/gallon. This is an alternate calculation method and is identified by "2" (Gross heating Value Gal 2) -Gross Heating Value BTU/Gallon as a liquid -Net Heating Value BTU/lbm as a liquid -Net Heating Value BTU/gallon as a dry gas -Net Heating Value BTU/gallon as a liquid -Component Volume (Cu Ft / Gal) [+] [NGA] Added physical constants for Gross Heating Value BTU/LBM as Liquid and Net Heating Value BTU/LBM as Liquid to TP-17 and GPA 2145-09 data sources. [+] [NGA] Added physical constants for Gross Heating Value BTU/LBM as Liquid and Net Heating Value BTU/LBM as Liquid to the 3 "NGL Default" configuration files using data from TP-17 and 2145-09 [+] [RDB] Updated the Results Database schema from version 3.01.00 to 3.03.00 to support the new NGA/NGL results. You will be prompted to upgrade existing databases when you start the software. [+] [ALL] Added the following enhancements to the Customize Results table in the configuration editor: -The result description is now displayed in the last column -The results that are included in the report are now highlighted in yellow to make them more visible. Version 3.0.2.7 --------------- [+] [ALL] EZ Result Monitor - added processing delay after detecting a .ESD file to allow all channel results to be written to the export folder before processing. Version 3.0.2.6 --------------- [+] [ALL] Updated help file and reference manual. [+] [NGA] Added an option to print a Total Component Summary report for C6+/Extneded analysis reports. The report includes the mole%, weight%, and liquid vol% for all standard and extended range components normalized to 100%. Version 3.0.2.5 --------------- [+] [ALL] Updated help file and reference manual. [-] [NGA] Fixed error when loading and display of old configuration files with monitored parameters based on C6+/extended fraction results. Version 3.0.2.4 --------------- [-] [ADO] Fixed problem with saving a paramaeter with the ADO module active, but no analog output channel defined. Version 3.0.2.3 --------------- [+] [NGA] Enhanced the ChemStation export macro to export Peak Summing results for Channel 1 only, as well as Compound Group results. [+] [LL] Added a "Support" start menu folder with a link to the EZReporter support resources on the Diablo Analytical Web Site. A shortcut to register the EZReporter COM objects was also added to the support folder. Version 3.0.2.2 --------------- [-] [ALL] Removed legacy code that would sometimes cause an error when starting EZReporter and loading a configuration file with paths that don't currently exist on the computer. [+] [NGA] The component constants in the NGL Default configuration files have been updated to GPA 2172-09 values where available. [-] [NGA] Fixed defect where the weight% and volume% were not being calculated correctly when manually reprocessing a data file using the "Tools > Edit current data set" menu option. [-] [ALL] the EZResult monitor now deletes .ESD and .SPL files automatically when an invalid comma delimiter error occurs. Previously, these files had to be cleared out manually. Version 3.0.2.1 --------------- [+] [ALL] You can now specify a starting and ending component number in a component loop in the export template file: {StartCompLoop,1} and {EndCompLoop,10} will export results for components 1-10. [-] [ALL] If no title or subtitle is specified, there is no longer a blank line printed in the report for those items. [+] [ALL] Added new option to report control to append additional text information to the end of the main printed report. The text to append is read from a simple text file. [+] [RDB] Updated the Results Database schema from version 3.00.00 to 3.01.00 to support the new extended fraction results. You will be prompted to upgrade existing databases when you start the software. [+] [NGA] First alpha release with support for additional extended fraction calculations. Version 3.0.2.0 --------------- [+] [NGA] The option to only print component results with amounts > 0 now also applies to the extended fraction summary report [+] [ALL] Added an option to disable the sample information prompt for connector and result monitors that support sample information variables. [+] [NGA] Added a new option to the NGL configuration that allows the extended fraction results (MW, Density, etc.) to be used as the C6+ calculation constants in a "Separate" report. Version 3.0.1.2 --------------- [-] [ALL] The EZ Result Monitor utility now only displays the last 100 runs in the result history table to prevent the table from becoming too large with time. [-] [ALL] The EZ Result Monitor utility now deletes the Sample Information files from all channels. [-] [ALL] Fixed a problem that required you to close the EZ Result Monitor utility before being able to restart EZReporter. [-] [NGA] Fixed incorrect "Volume Factor" (cu.ft./gal) entires in the TP-17 standard data source for o-Xylene, 1,c2,c3-trmethylcyclohexane, and 1,1,2-trimethylcyclohexane. Also updated the default NGL configuration files to reflect these changes. Version 3.0.1.1 --------------- [-] [ALL] Updated the EZChrom Quick Start Guide to refer to use the EZ result Monitor utility for OpenLab EZchrom installations. Version 3.0.1.0 --------------- [-] [ALL] Changed the "Backup Current Config Files..." code to backup all ".LOG" and ".INI" files in the installation folder. [+] [ALL] Enhanced all of the "Connector" programs used to transfer results from the supported data systems to process configurations with large component lists much more efficiently. [+] [ALL] Added the EZResultMonitor software utility as an alternative to the ProcessEZChromData "After Export" program to transfer results from EZChrom to EZReporter. EZResultMonitor polls the EZChrom export folder every second and processes results automatically when it finds an ESD file. This utility was written for two purposes - 1) to address a defect in the OpenLab version of EZChrom that results in the After Export program not actually being called after acquisition, and 2) to better support multi-instrument installations. Version 3.0.0.5 --------------- [-] [ALL] When activating the software or a feature, the registration info window is first displayed so that the serial number and other registration info is more likely to be saved. [-] [ADO] Fixed error that would be generated when activating the ADO feature from the I/O Module tab. [-] [ADO] Fixed context links to the help file for several of the ADO mosule "Help" buttons. Also added "Help" buttons to the Analog Output and Alarm Output tabs of the monitored parameter configuation window. Version 3.0.0.4 --------------- [-] [ALL] Addressed a change in the format of the Acquisition Date string produced by the OpenLab version of EZChrom in which a GMT offset is appended to the standard date string. This causes problems with formatting of date strings, date-based queries of the Results Database, etc. Consequently, the EZChrom Connector checks for the presence of the GMT offset string in the Acqusition Time field, and strips it from the date string if it is found. [-] [ALL] Fixed problem with the printed parameter report where if the low alarm status was "Pass" it would overwrite the "Fail" status string of the high alarm. Version 3.0.0.3 --------------- [+] [ALL] Fixed problem with the EZChrom and EZ IQ connector when using sample-specific processing that would result in several of the sample info fields in the header being cleared. [-] [STD] Fixed potential problem with Sample Specific Processing sample names containing SQLite reserved characters ('). Version 3.0.0.2 --------------- [-] [ALL] Fixed a minor problem with the "File > Open" menu option under Win7 where the file dialog was not initializing to the default data folder. [-] [ALL] The code that checks for the original configuration file when loading an EZReporter ".BTU" data file has been modified to check both the original location stored in the file as well as the settings folder in the current application path. [-] [ALL] Removed all fixed paths from the default configuration files so that both C:\Program Files\ and C:\Program Files (x86)\ are supported. [-] [NGA] Disabled the NGL configuration check of Last Std Comp < First Ext Comp. This allows you to set the Last Std comp so that all of the extended components are included in the standard report (Separate report format only). [-] [NGA] Enabled calculation and reporting of extended relative gas density. [+] [NGA] Added new physical property data sources and default configuration files for the following ISO 6976 combustion/metering temperatures: 0/0, 15/0, 25/0, and 20/20 Deg C. Version 3.0.0.1 --------------- [+] [STD] You can now customize all of the titles and labels on the printed report using the new "Report > Report Titles" table in the configuration table. [-] [NGA] Fixed incorrect physical property values for the superior heating value (KJ/mol) for Methane and n-Hexane, and Inferior Heatnig Value (KJ/mol) for Methane at 25 DegC in the physical property database and the ISO 6976 (25-20 Deg C).cfg configuration file. [+] [RDB] Added new ASTM D2598-02 result to the NGAResults Results Database table and pdated the database schema to version 3.0.0 The user will be prompted to run the automatic database upgrade when EZReporter is started. [+] [NGA] Added ASTM D2598 Vapor Pressure (psia) as a new result in addition to ASTM D2598 Vapor Pressure (psig). Version 3.0.0.0 --------------- [+] [ALL] Updated license and licensing components. Existing users will have to reactivate the software. [+] [ALL] Updated license recovery program to use new licensing components. Version 2.1.0.4 --------------- [+] [STD] Updated reference manual and help file to reflect new features and user interface changes. [-] [NGA] Fixed error in the calculation of Gross Heating Value (btu/cuft) for the extended C6+ fraction. [+] [STD] Updated Print Settings to include new configuration settings. [+] [NGA] In the manual entry window the component amount column is now labeled with the required units for the configuration - Mole%, Wt%, or Vol%. [-] [NGA] Modified the standard components data sources list so that the list order can be changed independently of the data source ID. [+] [STD] Added a new option to the "Report" configuration allowing PDF reports to be saved when automatically processing results. [+] [STD] Added a warning when saving the configuration if the component table or sample information table is edited in a way that could break Export Template variable or Calculated Result formula references. [+] [STD] Added an option to Report Control to include only components with amount > 0 in the displayed/printed component report. [-] [STD] The label setting for the "Sample Name", "Operator", and "Sample Notes" results in the Report > Customize configuration is now also applied to those same fields in the Sample Information section of the Manual Data Entry window. In addition, if you disable any of those results in the report, they will also not be displayed in the manual data entry window. [-] [RDB] Added code to allow text strings containing apostrophe characters to be saved in the results database and queried. [+] [RDB] Updated the database schema to version 2.3.0 The user will be prompted to run the automatic database upgrade when EZReporter is started. [+] [RDB] Added new ASTM D2598-02 results to the ComponentResults and NGAResults Results Database tables. [+] [NGA] Added physical properties, calculations, and results for ASTM D2598-02 Vapor Pressure and Relative Density. [+] [STD] Added configuration options to set the printed report margins. [-] [STD] The component table in the manual entry window now displays the number of decimal places specified in the Calculation Settings (it had been fixed at 3 decimal places). [+] [RDB] Added a new CalculatedResults table to the Results Database. [+] [STD] Introduced Calcualted Results: results that are calculated from user-defined formulas using other component and summary results as variables. Calculated results can be displayed in the printed report, exported to text file, and displayed in the parameter table. Version 2.1.0.3 --------------- [+] [STD] Updated reference manual and quick start manuals. [+] [STD] Added a Quick Start Guide for the Cerity data system. It is installed if Cerity is detected on the target computer. [+] [NGA] Added a default GPA 2177-03 configuration file. [-] [STD] Fixed problem with horizontal scrollbars not showing on the Sample Specific Processing configuration dialog. [-] [NGA] Addressed rare situation where a divide by zero error would occur when calculating the water content correlation. Version 2.1.0.2 --------------- [+] [NGA] Added GPA 2177-03 Calculation Check configuration and data file. [+] [RDB] Added the new results to the NGAResults table and Updated the results database schema to version 2.0.1 Older versions will be upgraded automatically when EZReporter is started. [+] [NGA] Added the following new results: Vapor Pressure in psig, and Total Liquid Density calculated directly from the relative liquid density rather than from the sum of the component liquid densities. This result is labeled with a "2" suffix in the configuration/report (Total Liquid Density 2). [+] [NGA] Added the ability to specify raw component units in volume% to support the GPA 2177-03 standard. The corresponding weight% and mole% are then calculated from the volume%. Note: In this mode, the "wet" and "sat" results are *not* calculated. [+] [NGA] The raw component units (mole%, weight%, volume%) can now be set independent from the NGL/Extended reporting option. The selection of raw component units was moved from the NGL configuration tab to the main NGA tab. >> Merged changes from 2.0.1.0 maintenance branch to main development branch << [+] [STD] Updated license recovery tool to use new installer engine. [+] [STD] Updated installer engine and made minor cosmetic modifications to UI. [-] [STD] Fixed printing problem with the report results after using the "Select All" context menu. [-] [STD] Fixed customize report context menu - "Select None" which would deselect the component name. [-] [NGA] The standard T and P are now stored with the physical property data data source rather than the calculation type. [+] [NGA] Added validation checking to prevent standard physical property data for a different base temperature from being transferred to the configuration. [-] [NGA] Fixed problem where the relative gas density was not being calculated for saturated and wet samples when using the ISO 6976 configuration. [+] [NGA] Added a new default configuration, "ISO 6976 (25/20 Deg C).cfg", which has physical properties from the ISO 6976 Standard at a combustion temp of 25 Deg C and a Metering temp of 20 Deg C. [-] [NGA] Fixed problem when transferring NGA calcualtion factors from a standard data source to the current configuration. [+] [NGA] Added ISO 6976 25/20 physical property data source. >> Merged changes from 2.0.0.3 maintenance branch to main development branch << Version 2.1.0.1 --------------- [-] [RDB] Fixed error that would occur when trying to use sample history alarms with the TotalRawAmount and TotalNormAmount paramaters. [+] [NGA] Added a new default configuration file for refinery gas applications, "Refinery Gas.cfg". Version 2.1.0.0 --------------- [-] [NGA] The NGL/Extended Analysis Quick Start Guide is now integrated into the reference manual, and the separate quick start guide removed from the distribution. [-] [STD] Fixed a problem with the ChemStation Connector application that would result in the Injection Date month and day being swapped in certain circumstances. [+] [ADO] Added a Quick Start Guide and Help file for the I/O Module. [+] [STD] The EZChrom/EZIQ Connector can now automatically determine the delimiter character used in the EZChrom ESD export files. Select this new option from the Connector's "Options" menu. You can still force the Connector to use tab or comma delimiters by selecting those options from the "Options" menu. [-] [STD] Fixed problem with component amounts in EZChrom/EZIQ tab-delimited ESD files not being parsed correctly. [+] [ADO] Added a new Analog and Digital I/O Module that provides analog outputs for parameter values, and digital outputs for parameter alarm actions. This module currently requires the National Instruments Compact FieldPoint hardware. [+] [STD] Added "Text Alarms" to the parameter configuration. These alarms are set based on the value of a text parameter. [+] [STD] Added the ability to display a limited number of sample information results in the parameter table (Sample Name, Sample ID, etc.) as Text Parameters. Version 2.0.0.0 (Release Candidate 1) --------------- [+] [STD] Updated the help file, reference manuals, and quick start guides. The instructions for configuring the chromatography data system for use with EZReporter has been moved from the main reference manual to a the quick start guide for the specific operating system. [+] [RDB] Added new NGL results to Results Database. [-] [STD] Fixed problem with the EZChrom Connector not properly parsing the sample information from ESD files when the channel name contains a comma. IMPORTANT: to enable this fix, you must configure EZChrom to export the Sample Information Report in the Method > Advanced dialog. [-] [STD] Fixed multiple errors that would potentially occur when "Clearing" the component list. [-] [STD] Fixed problem with validation of custom numeric sample information fields. [-] [RDB] when null numeric import values are encountered they are converted to "0" to prevent an error that would occur when adding the null result to the database. [+] [STD] Added "registration.dat" to the configuration backup. [+] [STD] The License Status window now includes a "Registration Information" button that allows the current serial number and registration information to be entered or reviewed. [+] [STD] License activation dialog now prompts for serial number and registration contact information and includes this information in the activation request forms. In addition, this information is saved in "registration.dat" and the serial number and registered company are displayed in the "About" window if they have been entered. [-] [STD] Fixed an error in the ChemStation Connector "EZRPT.MAC" that would occur if the first character of the comment field in the run/sequence was an "invalid" character (CR, LF, etc.) Now, those characters are properly replaced by spaces. [-] [STD] Fixed problem with validation of custom numeric sample information fields. [-] [RDB] when null numeric import values are encountered they are converted to "0" to prevent an error that would occur when adding the null result to the database [+] [STD] A window is now displayed upon startup allowing the user to choose a default configuration file the first time the software is started on a new computer, or if the last configuration file that was loaded is missing. [+] [STD] Added a "Splash" screen on startup to display status during initialization to let the user know that the software is "alive" when loading the software. [+] [NGA] Added ISO 6976 Physical Properties, Calculations, and Results [+] [NGA] The base physical property data source is now saved as part of the configuration file. You can edit/assign the data source in the NGA configuration tab and copy the associated calculation factors to the configuration. [-] [NGA] The NGA calculation factors have been moved to a table instead of individual text boxes to accomodate new ISO and NGL factors. [+] [STD] Added a new default configuration, "STD Default.cfg" file for Standard, non-natural gas installations. [+] [NGA] Added ISO 6976 default configuration (ISO Default.cfg) and Calculation check configuration (ISO 6976 Calculation Check.cfg) and data file. [-] [NGA] Renamed the Default configuration files: "hexanes plus.cfg" is now "C6+ Default.cfg", "default.cfg" is "NGA Default.cfg". Version 1.0.9.2 --------------- [+] [NGA] Added Natural Gas Liquids (NGL) Quick Start Guide to the distribution. [-] [STD] Fixed error when the "Delete" button on the parameter configuration tab was clicked with no parameters defined in the table. [+] [NGA] Added GPA 2186 "template" configuration files for "separate", "combined", and "combined and corrected" formats. These configurations include all of the extended components from the GPA TP-17 standard, and can be edited to match a specific application. [+] [NGA] Added extensive support for GPA 2186 type natural gas liquids extended (C6+) fraction support including separate/combined reporting of the extended fraction and correction of extended fraction raw amounts using a "bridge" correction factor. Also, several new extended fraction results can be included in the printed report and in export text files. Version 1.0.9.1 --------------- [+] [NGA] Added an option to the unknown components dialog (from the standard components transfer feature) that allows the "append as new component" option to be be applied to all unknown components. This makes it easier to create configurations containing a large number of standard components. [-] [STD] Adjusted refresh of various component tables to improve performance when loading or updating the tables with large numbers of components. [+] [NGA] Added GPA TP-17 (1998 Revision) standard physical property data source. [+] [NGA] Added support for accepting component raw amounts in Weight%. Mole% amounts are then calculated from Weight%. This option is only intended for use in Natural Gas Liquids applications. Water content is ignored and only the "Dry" Mole% and other results are calculated. Version 1.0.8.2 --------------- [-] [NGA] Added SUMGPM as an alias for the export variable TOTALGPM, COMPRAWMOLEPCT as an alias for COMPRAWAMOUNT, and SOURCEDATAFILEPATH as an alias for SOURCEDATAFILE to provide backward compatibility with older BTU Calculator export templates. [-] [STD] Fixed problem where exported injection or report dates were being truncated with certain custom format strings. [-] [NGA] Added CompNormMolePct and CompNormMolePctDry as aliases for the export variable CompNormAmount to provide backward compatibility with older BTU Calculator export templates. Version 1.0.8.1 --------------- [+] [STD] Updated the help file and reference manuals. [-] [RDB] Fixed a problem where the original configuration file was not being loaded when that option was checked while reprocessing database results. [-] [STD] Reduced the margins on the configuration settings report to prevent the report results table from wrapping in portrait orientation. Also added the configuration file name (without path) to the footer. [-] [NGA] Updated the default configuration files to include the newly-added physical properties where they are available. [+] [NGA] Added the following new default configuration files and correspopnding example data files that can be used to check/validate the EZReporter NGA Calculations. GPA 2172-09 Calculation Check at 14.696 psia.cfg GPA 2172-09 Calculation Check at 14.65 psia.cfg GPA 2172-09 Example Data at 14.696 psia.btu GPA 2172-09 Example Data at 14.65 psia.btu [-] [NGA] Eliminated the "wet" versions of the default configuation files and added water as the last component to the following default files: GPA 2145-09.cfg, GPA 2145-03.cfg, default.cfg, hexanes plus.cfg, ASTM D3588-98 (2003).cfg [+] [RDB] Custom numeric formats are now applied to both summary and detailed numeric results displayed in the Results Database tables. [+] [NGA] Added Cu. Ft. / lb-mol as an editable configurtion setting in the "Other NGA/NGL Calculation Factors" section of the "Natrual Gas Analysis" tab. This setting is used in the calculation of absolute liquid density. [-] [STD] The option to apply the number of decimal places specified for component amounts to all numeric results has been removed. Customizing the numeric format of other results is now handled through the report/result customization table. [+] [STD] The formatting of individual numeric results can now be customized in the Report | Customize table of the configuration editor. Note that the formatting of component and related total amounts is determined by the number of decimal places set in the "Calculations" tab of the configuration editor. [-] [STD] Duplicate component names are not allowed in the configuration component table. An alert is now displayed if any duplicate names are found when saving the configuration. [+] [STD] Added context menu options to the component configuration table to add, clone, or delete a component. [+] [RDB] Updated the results database schema to 1.0.8. Older versions will be upgraded automatically when EZReporter is started. [+] [RDB] Added the new results listed below to the ComponentResults, NGAResults, and SampleResults tables of the Results Database. [+] [NGA] Added the following new results to the NGA report: -Component Normalized Liquid Volume% -Component Gross Heating Value (BTU / gal.) -Component Relative Liquid Density -Component Vapor Pressure (psia) -Component Absolute Liquid Density (lbm / gal.) -Total Normalized Liquid Volume% -Total Gross Heating Value (BTU / gal.) -Total Relative Liquid Density -Total Vapor Pressure (psia) -Total Absolute Liquid Density (lbm / gal.) -Total Absolute Liquid Density (lbm / bbl) -Total Volume (cu. ft. / gal.) -API Gravity [+] [NGA] Added the following physical properties to the standard components and component configuration tables. The standard component database was updated to include the corresponding values from GPA2145-09, GPA2145-03, ASTM D3588-98, and the GPSA Eng. Databook (12th Ed.) where avaialble. -Gross Heating Value (BTU / gal.) -Relative Liquid Density -Absolute Liquid Density (lbm / gal.) -Vapor Pressure (psia) Version 1.0.7.1 --------------- [+] [STD] Updated the help file and reference manuals. [+] [NGA] Updated the "GPA 2145-09 Migration Guide" to reflect the EZReporter NGA screen shots, and renamed it, "EZReporter NGA Physical Property Update Procedure". [+] [NGA] Definitions of the physical properties in the standard components table are now added automatically to the end of a standard physical property printed report. [+] [STD] Added a context menu to the report/result configuration table that allows you to select all results, no results, or the factory default results. In addition, you can reset the report labels to the factory default values. [+] [NGA] Added a context menu to the standard components physical property table that allows you to select all components, no components, or select those components whose name matches a component in the current configuration. [+] [NGA] Added a dialog to select which properties to copy from the standard components physical property to the configuration. This allows configurations to be assembled more easily from multiple physical property data sources. [-] [NGA] Updated the default configuration files to include the newly-added physical properties where they are available. [-] [NGA] Fixed minor problem with transfer of standard component properties to the configuration component table. [-] [STD] Fixed problem where the custom report settings were not always being set correctly when a new configuration file was loaded. [-] [STD] Fixed problem where multiple EZReporter Data File entries would be included in the report header. [-] [STD] Only the report settings (Include in Report, Report Title) that have been changed from their default settings are written to the configuration file. This allows changes to the default settings to be propagated to existing configuration files. [+] [STD] Added an option to the export configuration that allows you to set the file extension of the export file. However, if you have selected a Fixed Export File that already includes a file extension, it will take precidence. [-] [STD] Fixed problem with the export file being truncated after the last line in a component loop. [+] [RDB] Updated the results database schema to 1.0.7. Older versions will be upgraded automatically when EZReporter is started. [+] [RDB] Added the new results listed below to the NGAResults and ComponentResults tables of the results database. [+] [NGA] Added the following new results to the NGA report: -Component Gross Heating Value (BTU / lbm): Dry, Sat., Wet -Component Net Heating Value (BTU / cu.ft.): Dry, Sat, Wet -Component Net Heating Value (BTU / lbm): Dry, Sat, Wet -Component Ideal Gas Density (lbm / cu.ft.): Dry, Sat., Wet -Total Gross Heating Value (BTU / lbm): Dry, Sat., Wet. -Total Net Heating Value (BTU / cu.ft.): Dry, Sat., Wet. -Total Net Heating Value (BTU / lbm): Dry, Sat., Wet. -Total Ideal Gas Density (lbm / cu.ft.): Dry, Sat., Wet -Total Real Gas Density (lbm / cu.ft.): Dry, Sat., Wet [+] [NGA] Added the following physical properties to the standard components and component configuration tables. The standard component database was updated to include the corresponding values from GPA2145-09, GPA2145-03, ASTM D3588-98, and the GPSA Eng. Databook (12th Ed.) where avaialble. -Net Heating Value (BTU / cu.ft.) -Net Heating Value (BTU / lbm) -Gross Heating Value (BTU / lbm) -Ideal Gas Density (lbm / cu.ft.) Version 1.0.6.5 --------------- [-] Addressed a potential problem where an invalid configuration file name in ezreporter.ini would prevent a valid configuration file from being loaded. The default configuration file is now loaded in this situation. [-] Fixed help button on the parameter configuration dialog not mapped to the correct help context ID. [-] Fixed a defect where the parameter format string was not being initialized and displayed in the configuration dialog. Version 1.0.6.4 --------------- [+] A "Standard Edition" manual is now included in the distribution. NGA and Results Database topics are excluded from this version of the manual. [-] Results Database: Fixed minor problem with date select dialog. [-] Results Database: Updated the database schema version to 1.0.6. Older versions will be upgraded automatically when EZReporter is started. [-] Results Database: Made modification to the results database schema so that injection and report date searches work correctly. [-] Minor fix to prevent water content calculation from being performed when NGA calculations are disabled or inactive. Version 1.0.6.3 --------------- [+] Updated the reference manual and help file. [-] A few minor fixes to the configuration editor and configuration report. Version 1.0.6.2 --------------- [+] There are now default numeric formats for each numeric result displayed in the report. If you uncheck the "Apply to report" checkbox in the calculations tab of the configuration editor, the default formats will be used instead of a format based on the number of decimal places specified for component amounts. Note 1: All component amount (Mole%, Weight%, etc.) and related total amounts will still use formatting based on the number of decimal places specified in the calculations tab. Note 2: The default numeric fomats as displayed in the report can not be changed at this time. However, it is still possible to enter custom formats for monitored parameters and exported results. [-] Fixed logic of disabing/enabling of NGA settings when the NGA module is not activated or NGA calculations are disabled/enabled. [+] The configuration backup utility now prompts whether you want to include the results database in the backup. [+] Added a "Print Configuration" dialog that allows you to select which settings you want to print. [+] Updated the configuration printing function to include new settings. [-] Fixed wrapping of component parameters table when printing the configuration. [-] Fixed incorrect report label for Flowing Pressure. Version 1.0.6.1 --------------- [+] NGA: Added option to prompt for Flowing Temperature and Pressure and to calculate the water content correlation based on the GPA 2145-09 & IGT RB8 standard. The calculated "as delivered" water mole fraction is reported as the "Wet" results. [-] Results Database: Updated the database schema version to 1.0.5. Older versions will be upgraded automatically when EZReporter is started. [+] Results Database: When new results are saved to the database, the new result is now automatically selected and displayed in the sample results summary table. [+] The new sample information result "ResultComment" was added to the report and results database. [+] Added a Result Confirmation screen that can be displayed before a result is added to the database. It displays the current parameters and alarms and gives the option to Accept, Reject, or cancel adding the result to the database. In addition a Result Comment can also be entered and save in the results database. If the text file "resultcomments.dat" is present in the EZReporter program folder, then each line present in that text file will be added to the Result Comment list box to provide a structured set of comment strings. [-] The sample results summary and detail tables are now cleared after deleting all results and when queries return no results. [-] Disabled editing of parameters directly from the main parameter table. Parameters should be edited from the configuration window. [+] Right clicking on a component parameter in the parameter configuration table displays a context menu that allows you to add the remaining components in the configuration to the parameter table using the selected parameter as the template. [+] Right clicking on a parameter in the parameter configuration table displays a context menu that allows you to clone the properties of the selected parameter to a new parameter. [+] The order of parameters displayed in the parameter monitoring table can now be changed by dragging a row in the parameter configuration table to a new location. This is done by 1) selecting the row you want to move by clicking it with the left mouse button, and 2) click and hold the right mouse button and drag the row to the new postion. [+] Implemented sample history alarm limits for the parameter alarms. This option is available if the results database is activated or in trial mode. [-] Results Database: Fixed a defect where the NGA statistics were not being calculated correctly when the limit parameter was set. Version 1.0.5.8 --------------- [+] Report printing algorithm enhanced so that a long value in the Sample information table that exceeds the page width is truncated with ending ellipses (...) to prevent the table from breaking onto a new page. [+] Report printing algorithm enhanced so that when the component results table exceeds the page width, the extra results are printed in a new table below rather than causing an immediate page break. Version 1.0.5.7 --------------- [-] Results Database: Fixed the result comparison dialog not getting the norm mole% values from the correct database field and returning "0". [-] Report header results that are file names (configuration file, source data file, etc.) now are displayed as only the file name with the full path removed. This is to prevent long paths from causing the report to break onto a new page. [-] The Batch Process dialog no longer disables the "Export" option if the Automatic export option is disabled in the configuration. This allows the user to batch export results that were collected offline once they are hooked up to the network. Version 1.0.5.6 --------------- [-] If the water amount is added manually for a "Wet" calculation, it is included in the Raw component amounts. The TotalRawAmount includes the raw water amount, while the TotalRawMolePct excludes the raw water amount. [-] Fixed handling of water content in "NGA" vs "Standard" edition. Water is included in NormAmount/normalization in the Standard Edition. Water is excluded from NormAmount/Normalization in the NGA Edition: In the NGA edition NormAmount is the Normalized Mole% (Dry). [-] Results Database: The Import dialog now properly displays a warning if either the import template or import file have not been set to a valid file. [-] Results Database: Fixed defect that caused the Sample Information (SampleName, InjectionDate, etc.) to not be saved to the database during Import. [+] Results Database: Display of import template and import file in Import Results dialog box now uses a "Compacted Path" if the path is too wide to display in the given label area. Version 1.0.5.5 --------------- [+] The document name used for the printed report is now set to the sample name. If the sample name is blank the document name is set to "EZReporter Report" rather than "Document". [-] Results Database: The Batch Process dialog has been modified so that the Batch Plot and Batch Export options will be disabled if the current configuration has not been set up to use those features. [-] Results Database: The Batch Process dialog "Abort" button will now close the dialog if an error occurs during processing. Version 1.0.5.4 --------------- [+] Updated help file and reference manual. [-] Fixed defect where normalized weight% was not being corrected properly for rounding error for negative differences. [+] Results Database: Added a "Cancel" option to the database upgrade dialog. If the user cancels the upgrade, the results database will be disabled. [-] Results Database: Updated the database schema version to 1.0.4. Older versions will be upgraded automatically when EZReporter is started. [+] NGA: Added internal support to implement the GPA 2145-09/IGT RB 8 Water Content Calculation in a future version. [+] NGA: Added "Sat" and "Wet" component results for Gross Heating Value, Relative Density, GPM, and Compressibility/Z. [+] Results Database: Added an option to the database import dialog to set the ExportStatus field so that imported results are not re-exported. [+] NGA: Added ASTM D3588-98 (2003) physical properties to the Standard Components table. [-] NGA: Printing the Standard Components table now includes all properties present in the table. [-] If no raw component amounts are present, but Norm Amounts or Norm Mole% are, the normalized values will be used when processing/calculating results. this situation occurs when results are imported into the results database without the raw amounts. [-] If values already exist for custom sample information fields, they will be displayed in the "Edit Current Data Set" dialog instead of the default or recalled values. [-] Results Database: Changed the order of the buttons so they conform better to workflow (left to right). [+] Results Database: Import Results now has an option to append to or replace the current results with the imported results. [-] Results Database: The Import Results button has been moved from the configuration screen to the main Results Database screen. [-] Results Database: Moved TotalNormAmount from the NGAResults table to the SampleResults table. Existing results database files will be upgraded on startup. [+] Made significant enhancements to the internal reporting and processing architecture to allow new results to be calculated and displayed in the report more easily. [+] NGA: Added the following new physical properties and calculations to the NGA module: Physical Properties: -MolarMass (GPA 2145-09, GPA 2145-03, and GPSA Eng. Data Book) Calcualtions/Results: -Component Molecular Weight (Dry, Sat., Wet) -Total Molecular Weight (Dry, Sat., Wet) -Component Normalized Weight% (Dry, Sat., Wet) [+] ChemStation Connector: Modified the "ezrpt.mac" macro so it Adds an option to the ChemStation "Report" menu to generate an EZReport. [+] GPA 2261 repeatability or reproducibility limits are now included in the standard component tables for all data sources. [-] NGA: Standard component physical properties are now stored in an SQLite database to facilitate addition of new properties and data sources. Both the component configuration table and the standard component table were modified to support this change. Version 1.0.4 ------------------ [-] Fixed a problem with internal object references that could cause customized report options to be ignored when processing results automatically from a chromatography data system. [+] Updated the help file and reference manual [-] The component report table's behavior has been changed so that it now displays water as a component if present in the component list. This was done so that the Component Sat/Wet mole% results also include the water result. [-] The "Component Name" column of the component results table is now frozen so that the component name is always visible when scrolling horizontally, or when the table is split between multiple pages. [+] Added calculation of the following new results: -Component Norm% (Water Saturated) -Component Norm% (Wet) -Total GPM (Water Saturated) -Total GPM (Wet) These results are available for display in the report, parameter window, and for export. They have not yet been added to the Results Database. [+] The Report configuration now includes a "Customize" tab that displays a table of the results that are availble to include in the displayed/ printed report tables. You can now customize the results labels, as well as set whether or not a result is included in the report. [+] Enhanced the custom sample information fields to allow an unlimited number of fields and improve adding, deleting, and rearranging the order of fields. In addtion, you can now set whether or not a field is included in the printed/displayed report. [+] Added a menu option under "Tools" to backup the current configuration and log files to a zip file and optionally copy it to a folder on a flash drive or other location. Version 1.0.3 ------------------ [-] Modified the software version resource to include an explicit build version. [-] Modified the results database import function to handle import files containing blank lines without generating an error. [-] Changed the way that import/export/data files are opened and initialized. This addresses a intermittent problem with the files not being opened correctly prior to reading/scanning them. Version 1.0.2 ------------------ [+] Updated the help file and reference manual. [-] Updated the EZChrom and ChemStation connector programs so that they display an error in their log windows if EZReporter is not running when they are called. Having the connector start EZReporter and then process results has never been reliable. [-] Updated the EZChrom Connector (ProcessEZChromData.EXE) so that it can read tab-delimited files from EZChrom. You must configure EZChrom and the EZChrom Connector software to use tab delimiters if you want to use commas in component names (1,3-Butadiene for example). [-] Updated the EZReporter ChemStation macro (ezrpt.mac) so that component names in the "ezrpt.txt" file are contained within quotations. This allows component names with commas to be processed correctly by the ChemStation Connector software. [+] Added shortcuts to the EZChrom Connector and ChemStation Connector software to the EZReporter start menu program group. Version 1.0.1 ------------------ [+] Enhanced the EZChrom connector program (ProcessEZChromData) so that it recognizes and processes external standard report files (*.ESD) from non Micro GC instruments that use different signal/trace labels. [+] Updated reference manual and help file. [+] Enhanced the Results Database processing configuration to enable/disable display of sample history, to limit the number of results displayed, and to filter the results based on result status. [+] Enhanced the Results Database find record dialog to limit the number of results returned when searching by sample name. [-] Reworked display of the sample history to deal with results with the same sample name but different numbers and names of components. This also has improved the speed of generating the history table. [-] Fixed problem where the sample history display was being updated twice when a new result was added to the Results DB during auto processing. [+] Added a sample-specific configurations processing capability. Updated the EZChrom, Cerity, and ChemStation "connectors" to support this feature. Version 1.0.0 ------------------ [-] RC3: Enhancements to the ChemStation Connector program and macro to support the "B" rev ChemSTations with Unique Folder Creation on. [-] RC3: Fixed a problem with the results database import function using the wrong default folder and import template file. [-] RC3: Component GPM values are now corrected for gas compressibility as specified in GPA2172-09. [+] RC2: Added a refinery gas analysis configuration (refinerygas.cfg) file that can be used as a starting point for setting up a refinery gas analyzer. [-] RC2: Added ChemStation data processing via the ezrpt.mac macro and ChemStation "Connector" program, ProcessChemStationData.exe. The macro file is copied to the ChemStation "Core" folder automatically during installation if a ChemStaton is detected on the computer. [-] RC2: Fixed problem with labeling the x-axis of history plots when switching between injection date/time and data points. [+] RC2: Added Wobbe Index (Dry, Sat, and Wet) to report, import/export variables, and Results DB. [+] RC2: Updated manual and help file. [+] RC1: Initial release. >>End of Readme<<