• Skip to primary navigation
  • Skip to main content

Diablo Analytical

A Technology and Development Company

Contact Us: (925) 755-1005

  • Home
  • About
  • Products
    • Software Products
      • Diablo EZReporter Software
        • Overview
        • Standard Edition
        • Natural Gas Analysis Edition
        • Natural Gas Liquids Edition
        • Results Database Module
        • Modbus Module
        • Downloads
        • Purchase
      • Diablo MPValve 5.0 Software
      • Mass Spec Software
        • NIST Mass Spectral Library
        • Adam’s Library
        • Mass Mountaineer
        • MS Sensor Software
          • Overview
          • Application Builder
    • Measurement Products
      • Diablo 5000B Real-Time Gas Analyzer
        • Overview
        • Parts and Supplies
    • Distribution Partners
  • Applications
    • Fuel Processing R&D
    • Natural Gas Analysis
  • Events
    • Diablo Analytical Events
  • Contact Us
    • Contact Diablo Analytical
    • Distribution Partners
  • 0 items$0.00
  • Support
    • Technical Support
    • Latest Announcements
  • Facebook
  • LinkedIn
  • Store

EZReporter 4.0 Natural Gas Liquids Edition

Natural Gas

The EZReporter Natural Gas Liquids (NGL) Module is designed to perform Natural Gas Liquids extended analysis and reporting for dual detector (TCD+FID) analyses such as those based on the GPA 2186/2286 standards where bridging or allocation calculations are required. The results from these calculations are available for reporting, monitoring, trend plotting, and exporting.

Home
Std. Edition
NGA Edition
Results Database
Modbus Module
Downloads
Buy Now

Overview

The EZReporter Natural Gas Liquids (NGL) Module is designed to perform Natural Gas Liquids extended analysis and reporting for dual detector (TCD+FID) analyses such as those based on the GPA 2186/2286 (and related) standards. The results from these calculations are available for reporting, monitoring, trend plotting, and exporting.

The EZReporter 4.0 Natural Gas Liquids Edition also includes a license for the Natural Gas Analysis module.

NGL Edition News

  • Version 4.0.19.3:  Added support for the GPA 2186-22 Bridging (FID Calibrated and Uncalibrated) and Allocation (FID Calibrated and Uncalibrated) calculations and GPA 2286-24 Bridging (FID Uncalibrated) and Allocation (FID Calibrated and Uncalibrated) calculations.
  • GPA 2145-16 Physical Constant Update

Sample Results View

ezr4-main-ngl-edition

Total Component Results View

ezr4-main-ngl-edition-total

C6+ Components View

ezr4-main-ngl-edition-c6

Additional Resources

  • NGL Edition Brochure
  • NGA/NGL Modules Reference Manual

Extended Fraction Calculation Methods

There are several different methods to calculate extended (Hexanes Plus) analysis results.  EZReporter 4.0 supports the following calculation methods:

  • Separate:  The TCD and FID extended analysis results are each calculated and reported separately.  The TCD results, including C6+, are used to generate the total sample results, while the FID results are used to generate the average extended fraction results.
    • Hybrid:  The FID extended fraction average results are calculated first and are then used as the constants for the TCD C6+ calculations.
  • Combined/Bridging:  The TCD and FID extended analysis results are combined into a common report with the option of applying “bridge” factors to normalize the relative response from each detector.  The C6+ results in the total sample report are derived from the individual combined FID extended component calculated results.  The Calibrated Raw Bridging calculation requires both the TCD and FID to be calibrated, and the bridging calculation is performed using the raw/un-normalized component amounts.  Uncalibrated FID calculation methods use peak areas and Unversal Relative Response Factors to estimate FID component concentration.
    • Calibrated Raw Bridging
    • GPA 2186-22 Bridging (FID Calibrated and Uncalibrated)
    • GPA 2286-24 Bridging (FID Uncalibrated)
  • Allocation:  The individual FID extended component amounts are first adjusted so that the total FID C6+ amount is equal to the total TCD C6+ amount.  The C6+ results in the total sample report are then derived from the individual combined FID extended component calculated results. The Calibrated Raw Allocation calculation requires both the TCD and FID to be calibrated, and the allocation calculation is performed using the raw/un-normalized component amounts. Uncalibrated FID calculation methods use peak areas and Unversal Relative Response Factors to estimate FID component concentration.
    • Calibrated Raw Allocation
    • GPA 2186-22 Allocation (FID Calibrated and Uncalibrated)
    • GPA 2286-24 Allocation (FID Calibrated and Uncalibrated)

Standard Component Data Sources

EZReporter 4.0 includes component physical property constants from the following standard data sources that can be used in the NGL  calculations:

  • GPA 2145-16
  • GPA 2145-09
  • GPA 2145-03
  • GPSA Engineering Data Book
  • GPA TP-17
  • ASTM D3588-98 (2003)
  • ASTM D2598-02 (2007)
  • ISO 6976
  • ISO 8973 (1977)

In addition, the component constants can be edited manually to use constants from other data sources.

Calculated Results

The following “average” results are calculated for the extended fraction:

  • Gross Heating Value (BTU / ideal cu. ft.)
  • Gross Heating Value (BTU / lbm)
  • Gross Heating Value (BTU / gal.)
  • Average Molecular Weight
  • Vapor Pressure (psia or psig)
  • Liquid Density (lbm / gal. and lbm / bbl)
  • Relative Liquid Density
  • Gas Density (lbm / cu.ft.)
  • Volume (cu.ft. / gal.)
  • API Gravity